Product Features:
(1) IGBT design with wide voltage range: -15% 380V ~ 440V +10%
(2) Excellent VVVF & Sensorless Vector Control Technology
(3) Competitive Price & Reliable Performance
(4) Removable Keypad & Standard Modbus-RTU communication
(5) Built-in PID & Simple PLC Function
(6) Easy parameter setting for commissioning
No. |
Model No. |
Motor Power |
Rated Current |
Outline Dimensions |
Package Dimensions |
Gross Weight |
(kw) |
(A) |
(H*W*D)(mm) |
(H*W*D)
(mm) |
(KG) |
V7 Series AC Drives Three phase AC 380V
(Voltage Range: -15% 380V~440V+10%) |
1 |
V7-0R7G/1R5P-T4 |
0.75 |
2.1/3.8 |
151*100*140 |
215*145*185 |
1.4KG |
2 |
V7-1R5G/2R2P-T4 |
1.5 |
3.8/5.1 |
1.5KG |
3 |
V7-2R2G/3RP-T4 |
2.2 |
5.1/8.5 |
1.6KG |
4 |
V7-4RG/5R5P-T4 |
3.7 |
8.5/13 |
240*140*180 |
310*185*235 |
3.6KG |
5 |
V7-5R5G/7R5P-T4 |
5.5 |
13/16 |
3.6KG |
6 |
V7-7R5G/11RP-T4 |
7.5 |
16/24 |
3.8KG |
7 |
V7-11RG/15RP-T4 |
11 |
24/32 |
3.9KG |
8 |
V7-15RG/18RP-T4 |
15 |
32/36 |
325*210*205 |
395*285*300 |
6.7KG |
9 |
V7-18RG/22RP-T4 |
18 |
36/44 |
6.8KG |
10 |
V7-22RG/30RP-T4 |
22 |
44/58 |
6.9KG |
11 |
V7-30RG/37RP-T4 |
30 |
58/70 |
465*285*225 |
560*390*335 |
17.8KG |
12 |
V7-37RG/45RP-T4 |
37 |
70/90 |
18.0KG |
13 |
V7-45RG/55RP-T4 |
45 |
90/110 |
510*320*255 |
605*425*355 |
24KG |
14 |
V7-55RG/75RP-T4 |
55 |
110/152 |
510*320*255 |
605*425*355 |
25KG |
15 |
V7-75RG/90RP-T4 |
75 |
152/172 |
650*380*275 |
765*480*325 |
41.5 |
16 |
V7-90RG/110RP-T4 |
90 |
172/205 |
41.6 |
17 |
V7-110RG/132RP-T4 |
110 |
205/253 |
41.8 |
18 |
V7-132RG/160RP-T4 |
132 |
253/304 |
750*495*325 |
850*595*395 |
69.5 |
19 |
V7-160RG/185RP-T4 |
160 |
304/380 |
71.3 |
|
Technical Index and Specification
Input |
Rated Voltage, |
3-phase(4T#sereis)380V;50/60HZ 1-phase(2S#series)220V;50/60HZ |
Allowed Voltage |
3-phase(4T#series)320V~460V 1-phase(2S#series)160V~260V |
Output |
Voltage |
4T#series; 0~460V 2S#series; 0~260V |
frequency |
Low frequency mode: 0~300HZ ; High frequency mode: 0~3000HZ |
Overloa d |
G type: 110% for long-term, 150% for 1 min, 180% for 5s
P type: 105% for long-term, 120% for 1 min, 150% for 1s |
Control Mode |
V/F control, advanced V/F control, V/F separation control, sensorless current vector |
Control Character |
Frequenc y Setting Resolutio |
Analog Input |
0.1% of maximum output frequency |
Digital Setting |
0.01 Hz |
Frequenc y |
Analog Input |
Within 0.2% of maximum output frequency |
Digital Setting |
Within 0.01% of set output frequency |
V/F Control |
V/F Curve (voltage frequency character) |
Reference frequency setting 5~600 Hz, multipoint V/F curve setting, or fixed curve of constant torque, low decreasing torque 1, low decreasing torque 2, square torque |
Torque Compensation |
Manual setting: 0.0~30% of rated output
Automatic compensation: according to output current and motor parameter |
Automatic
Current-limiting and Voltage-limiting |
During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chance |
Senseless Vector Control |
Voltage Frequency |
Adjust pressure/frequency ratio according to motor parameter and unique algorithm |
Torque Character |
Starting torque:
3.0 Hz 150% rated torque (VF control)
0.5 Hz 180% rated torque (SVC, FVC)
0.05 Hz 180% rated torque (VC)
Operating speed precision in steady state: ≤±
0.5% rated synchronous speed
Torque response: ≤50ms VC, SVC, FVC ≤20ms |
Motor Parameter Self-measureme nt |
Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control. |
Current and Voltage Restrain |
Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage |
Undervoltage Restrain during |
Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation |
Typica |
Multi-veloci ty and Traverse |
16 segments programmable multi-velocity control, multiple operation mode. Traverse operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut. |
|
FMZ Parts ( EMI Filter & Reactor ) can work for below branded VFD (AC Drive, Frequency inverter, Variable frequency drive, VSD, Inverter)
ABB, SIEMENS, DANFOSS, VACON, SEW, LENZE, PETER ELECTRONIC, LEISTER, WATT DRIVE, KEB, BONFIGLIOLI, NORD, CAG ELECTRIC MACHINERY, INTECNO, SYCOTEC, KB ELECTRONICS, TDE MACNO SPA, GEFRAN, CONTROL TECHNIQUES, PEPPERL FUCHS, GRUNDFOS, VEM MOTORS, BR INDUSTRI-ELEKTRONIK, RK ROSE+KRIEGER, CARLO GAVAZZI, LEROY SOMER, VERLINDE, TRANSTECNO, STAHL CRANE SYSTEMS GMBH, MIYACHI, DEMAG CRANES COMPONENTS, ABM, ROSSI, COGNITO QUAM, GE, AIRTECNICS, Delta, Teco, Toshiba, Mitsubishi, fuji, Yaskawa, Hitachi, Omron, Panasonic, HYUNDAI, LS/LG.
Key Words / Main Products:
Frequency inverter, inverter, AC Drives, frequency converters, frequency changers, adjustable speed drives (ASD), adjustable frequency drives (AFD), variable frequency drives (VFD), variable speed drives (VSD), Soft Starters, Soft Stop, Soft Starters for AC Motor, Motor Starters, Motor Soft Starters, EMI filter, Input EMI Filters, Output EMI Filters, AC Choke, AC Reactor, Input AC Choke, Output AC Choke, Input AC Reactor, Output AC Reactor, DC Choke, DC Reactor, Input DC Choke, Output DC Reactor, Input DC Reactor, HMI, Human Machine Interface,PLC,Programmable Logic Controller, Servo Drive, Servo Motor, Servo Motor & Drive, Servo Motor & Drive System
|
|
|